Phone: +91-8929127464, 011-47024300
Email: enquiry@w360.in

Fluke 15B+ Digital Multimeter

Fluke 15B+ Digital Multimeter

Fluke 15B+ Digital Multimeter

photo

Fluke 15B+ Digital Multimeter

  • 600 V Cat III safety rating
  • 50% bigger display with bright white backlight
  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A current
  • Diode test, data hold

Specifications: Fluke 15B+ Digital Multimeter

Accuracy Specifications

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).

FunctionRangeResolutionAccuracy
AC volts
(40 Hz to 500Hz)1
4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0% + 3
DC volts4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5% + 3
AC millivolts400.0 mV0.1 mV3.0% + 3
DC millivolts400.0 mV0.1 mV1.0% + 10
Diode test22.000 V0.001 V10%
Resistance
(Ohms)
400.0 ?
4.000 k?
40.00 k?
400.0 k?
4.000 M?
40.00 M?
0.1 ?
0.001 k?
0.01 k?
0.1 k?
0.001 M?
0.01 M?
0.5% + 3
0.5% + 2
0.5% + 2
0.5% + 2
0.5% + 2
1.5% + 3
Capacitance340.00 nF
400.0 nF
4.000 ?F
40.00 ?F
400.0 ?F
1000 ?F
0.01 nF
0.1 nF
0.001 ?F
0.01 ?F
0.1 ?F
1 ?F
2% + 5
2% + 5
5% + 5
5% + 5
5% + 5
5% + 5
AC current ?A
(40 Hz to 400 Hz)
400.0 ?A
4000 ?A
0.1 ?A
1 ?A
1.5% + 3
AC current mA
(40 Hz to 400 Hz)
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
AC current A
(40 Hz to 400 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
DC current ?A400.0 ?A
4000 ?A
0.1 ?A
1 ?A
1.5% + 3
DC current mA40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
DC current A4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
BacklightYes