Concrete Moisture Meter in Lucknow
 
                 
                
                A concrete moisture meter is a tool used to measure the moisture content in a concrete slab. This measurement is critical for preventing issues like blistering or adhesion failure of finished floor coverings, such as tile, wood, or vinyl, that are applied to the concrete.
| 
 Features  | 
|
| 
 6 % to 40 % moisture range on wood.  | 
 Separate pin type moisture probe, easy operation. & remote measurement.  | 
| 
 0 to 100% relative moisture value for Concrete and other non-wood material.  | 
 Records Maximum & Minimum reading with recall.  | 
| 
 Designed to check the moisture level of wood, concrete, gypsum and other non-wood material.  | 
 Data hold function to freeze the desired value on display. Auto shut off saves battery life.  | 
| 
 Microprocessor circuit assures maximum possible accuracy, provides special functions and features.  | 
 Heavy duty & compact housing case, designed for easy carry out & operation.  | 
| 
 Digital reading with large LCD display.  | 
 Built-in low battery indicator.  | 
| 
 General Specification  | 
||
| 
 Applications  | 
 Designed to check the moisture level of wood, concrete, gypsum and other non-wood material.  | 
|
| 
 Principal  | 
 Used the 2 pins electrode to measure the conductive ability of the species, then converter to the reading of % " Moisture of Content ".  | 
|
| 
 Function/Range  | 
 F1(Function 1) 
  | 
 6 % to 40 % moisture range on wood.  | 
| 
 F2(Function 2) 
  | 
 0 to 100% relative moisture value for Concrete and other non-wood material.  | 
|
| 
 
 F3(Function 3)  | 
 0.2 % to 50 % moisture range on gypsum.  | 
|
| 
 Resolution  | 
 0.1 %.  | 
|
| 
 Accuracy  | 
 ± ( 5 % + 5 d ) @ 23 ± 5 ℃  | 
|
| 
 Circuit  | 
 Custom one-chip of microprocessor LSI circuit.  | 
|
| 
 Display  | 
 13 mm ( 0.5" ) large LCD display,  | 
|
| 
 Probe  | 
 Separate 2 pins moisture electrode,  | 
|
| 
 Data Hold  | 
 By push button on front panel.  | 
|
| 
 Memory Recall  | 
 Records Maximum & Minimum reading value  | 
|
| 
 Power Off  | 
 Auto shut off, saves battery life, or manual off by push button.  | 
|
| 
 Sampling Time  | 
 Approx. 0.8 second.  | 
|
| 
 Data Output  | 
 RS 232 PC serial interface.  | 
|
| 
 Operating Temperature  | 
 0 to 50 ℃.  | 
|
| 
 Operating Humidity  | 
 Less than 80% R.H.  | 
|
| 
 Power Supply  | 
 Alkaline 006P, MN1604 (PP3) DC 9V battery.  | 
|
| 
 Power Current  | 
 Approx. DC 6.5 mA.  | 
|
| 
 Weight  | 
 330 g/0.73 LB  | 
|
| 
 Optional accessories  | 
 RS232 cable, UPCB-01. USB cable, USB-01. Data Acquisition software, SW-U801-WIN. EXCEL Data Acquisition software, SW-E802  | 
|